<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" ID="23927">
<titleInfo>
<title><![CDATA[PERBANDINGAN KINERJACOOLED LIQUIDDAN  COOLING FAN SEBAGAI PENURUN SUHU SISI PANAS ELEMEN TERMOELEKTRIK]]></title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Chuchuk Iswandanu Dian Wiratmoko</namePart>
<role><roleTerm type="text">Pengarang</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes"><![CDATA[mixed material]]></typeOfResource>
<genre authority="marcgt"><![CDATA[bibliography]]></genre>
<originInfo>
<place><placeTerm type="text"><![CDATA[JURUSAN TEKNIK]]></placeTerm></place>
<publisher><![CDATA[PROGRAM STUDI TEKNIK ENERGI TERBARUKAN]]></publisher>
<dateIssued><![CDATA[2017]]></dateIssued>
<issuance><![CDATA[monographic]]></issuance>
<edition><![CDATA[Publish]]></edition>
</originInfo>
<language>
<languageTerm type="code"><![CDATA[en]]></languageTerm>
<languageTerm type="text"><![CDATA[English]]></languageTerm>
</language>
<physicalDescription>
<form authority="gmd"><![CDATA[Text]]></form>
<extent><![CDATA[]]></extent>
</physicalDescription>
<note>Performance Comparison Cooled Liquid and Cooling Fan As Heat-Reducing Temperatures Thermoelektric Element



Chuchuk Iswandanu Dian Wiratmoko
Renewable Energy Engineering Study Program
Engineering Department


ABSTRACK

The use of a vapor compression cooling machine is very common today, It can pollute the environment due to refrigerant that is not environmentally friendly. Than, the authors do research in the development of a type of cooling machine model by using thermoelectric elements as a cold source. In this case there is a variety of literature that says that the lower the temperature of the hot side of the element the lower the cold side, Thr of literature researchers compared the performance between liquid cooling and air conditioning as a cooling side device. Testing do it for 1 hour with time interval of data taking every 10 minutes and 3 times repetition. From the test results it is known that the hot side with liquid cooling has a temperature difference 30C cooler than the air conditioner and the difference of Coefficient of Performance (COP) of both cooling models is 0.060.


Keywords : Thermoelektric Element, Cooled Liquid, Cooling Fan, Cooling Machine, Coefficient Of Performance.</note>
<subject authority=""><topic><![CDATA[TEKNIK ENERGI TERBARUKAN]]></topic></subject>
<classification><![CDATA[]]></classification><identifier type="isbn"><![CDATA[20200204]]></identifier><location>
<physicalLocation><![CDATA[E-Library POLIJE Sistem Elektronik Tesis Dan Disertasi]]></physicalLocation>
<shelfLocator><![CDATA[]]></shelfLocator>
<holdingSimple>
<copyInformation>
<numerationAndChronology type="1"><![CDATA[TET-SKRIPSI-2017-43]]></numerationAndChronology>
<sublocation><![CDATA[perpuspolije]]></sublocation>
<shelfLocator><![CDATA[TET-SKRIPSI-2017-43]]></shelfLocator>
</copyInformation>
</holdingSimple>
</location>
<slims:digitals>
<slims:digital_item id="9533" url="" path="/B42130463_LENGKAP.pdf" mimetype="application/pdf"><![CDATA[PERBANDINGAN KINERJACOOLED LIQUIDDAN  COOLING FAN SEBAGAI PENURUN SUHU SISI PANAS ELEMEN TERMOELEKTRIK]]></slims:digital_item>
</slims:digitals><slims:image><![CDATA[cover_B42130463.PNG.PNG]]></slims:image>
<recordInfo>
<recordIdentifier><![CDATA[23927]]></recordIdentifier>
<recordCreationDate encoding="w3cdtf"><![CDATA[2020-02-04 09:25:35]]></recordCreationDate>
<recordChangeDate encoding="w3cdtf"><![CDATA[2020-02-04 09:27:03]]></recordChangeDate>
<recordOrigin><![CDATA[machine generated]]></recordOrigin>
</recordInfo></mods></modsCollection>